Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 16 results
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_troubleshoot_FabricSwitchPowerFail_Alert
      Applies to MetroCluster FC FabricSwitchPowerFail_Alert Description MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected...Applies to MetroCluster FC FabricSwitchPowerFail_Alert Description MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. This article explains the cause and necessary actions to resolve these alerts.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/NVRAM_EXCESSIVE_CORRECTABLE_ECC_-_AutoSupport_Message
      Applies to AutoSupport Alert: NVECCA ONTAP Releases 9.1P18 and later 9.3P11 and later 9.4P6 and later 9.5 and all later releases Issue Summary This message occurs when excessive correctable error-corr...Applies to AutoSupport Alert: NVECCA ONTAP Releases 9.1P18 and later 9.3P11 and later 9.4P6 and later 9.5 and all later releases Issue Summary This message occurs when excessive correctable error-correcting code (ECC) memory errors are reported by the NVRAM complex. A proactive notification is sent by ONTAP once a critical amount of errors on a memory has been identified. [node: env_mgr: callhome.nvram.cecc:error]: Call home for NVRAM EXCESSIVE CORRECTABLE ECC.
    • https://kb.netapp.com/Legacy/AltaVault/How_to_replace_a_faulty_hard_disk_drive_on_AltaVault
      This KB article describes the procedure to replace a faulty hard disk drive on an AltaVault AVA-400, or AVA-800 appliance.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/HA_Group_Notification_NVRAM_EXCESSIVE_CORRECTABLE_ECC_ERROR_AFF_A700S_AutoSupport_Message
      Applies to AutoSupport Alert: NVECCM Platforms AFF A700S ONTAP 9 Issue Summary A proactive notification is sent by ONTAP once a critical amount of errors on a memory device has been identified.
    • https://kb.netapp.com/on-prem/Switches/Brocade-KBs/Brocade_firmwarecommit_failed_error
      Applies to Brocade Switch Issue Firmware upgrade failed with error firmwarecommit failed
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Correctable_memory_error_FAQ
      How do I check the status of the RMA or Engineer? What is the procedure to replace the DIMM? What steps should be done on the system in advance of the replacement? A takeover of the node where the mem...How do I check the status of the RMA or Engineer? What is the procedure to replace the DIMM? What steps should be done on the system in advance of the replacement? A takeover of the node where the memory needs to be replaced can be performed. The defective DIMM is called out in the case symptom What is the impact of leaving the identified DIMM in the system? The DIMM is degraded and might result in an unexpected disruption of the node.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/What_does_the_autosupport_message_FabricSwitchPowerFail_Alert_mean
      MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. FabricSwitchPowerFail_Alert is triggered when a powersupply of th...MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. FabricSwitchPowerFail_Alert is triggered when a powersupply of the MetroCluster backend switch has a failed power supply or a the power is interrupted.
    • https://kb.netapp.com/Legacy/AltaVault/AutoSupport_Message_AltaVault_Disk_Failed_ALERT
      AltaVault Disk Failed ALERT. AltaVault Notification: This message indicates that a disk has failed on an AltaVault.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/HCI_compute_host_crashed_with_uncorrectable_memory_error
      Hybrid Cloud Infrastructure host crashed with Faulty memory DIMM
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Handling_L2_Watchdog_Resets_on_the_AFF_A700s_Platform
      If node reboots, the following error can be seen in the EMS log files Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert...If node reboots, the following error can be seen in the EMS log files Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(n4-nht-fas-c03-02), system_down because l2_watchdog_reset. Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(n4-nht-fas-c03-02), system_down because reset_via_sp.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Health_Monitor_process_nphm_CriticalCECCCountMemErrAlertDIMM-X_ALERT_-_AutoSupport_Message
      AutoSupport Message - Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-X]) ALERT.  A proactive notification is sent by ONTAP once a critical amount of errors on a memory module has been ...AutoSupport Message - Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-X]) ALERT.  A proactive notification is sent by ONTAP once a critical amount of errors on a memory module has been detected.