Applies to MetroCluster FC FabricSwitchPowerFail_Alert Description MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected...Applies to MetroCluster FC FabricSwitchPowerFail_Alert Description MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. This article explains the cause and necessary actions to resolve these alerts.
Applies to AutoSupport Alert: NVECCA ONTAP Releases 9.1P18 and later 9.3P11 and later 9.4P6 and later 9.5 and all later releases Issue Summary This message occurs when excessive correctable error-corr...Applies to AutoSupport Alert: NVECCA ONTAP Releases 9.1P18 and later 9.3P11 and later 9.4P6 and later 9.5 and all later releases Issue Summary This message occurs when excessive correctable error-correcting code (ECC) memory errors are reported by the NVRAM complex. A proactive notification is sent by ONTAP once a critical amount of errors on a memory has been identified. [node: env_mgr: callhome.nvram.cecc:error]: Call home for NVRAM EXCESSIVE CORRECTABLE ECC.
Applies to AutoSupport Alert: NVECCM Platforms AFF A700S ONTAP 9 Issue Summary A proactive notification is sent by ONTAP once a critical amount of errors on a memory device has been identified.
How do I check the status of the RMA or Engineer? What is the procedure to replace the DIMM? What steps should be done on the system in advance of the replacement? A takeover of the node where the mem...How do I check the status of the RMA or Engineer? What is the procedure to replace the DIMM? What steps should be done on the system in advance of the replacement? A takeover of the node where the memory needs to be replaced can be performed. The defective DIMM is called out in the case symptom What is the impact of leaving the identified DIMM in the system? The DIMM is degraded and might result in an unexpected disruption of the node.
MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. FabricSwitchPowerFail_Alert is triggered when a powersupply of th...MetroCluster Health Monitor (FHM) AutoSupport messages are triggered when certain MetroCluster backend switch conditions are detected. FabricSwitchPowerFail_Alert is triggered when a powersupply of the MetroCluster backend switch has a failed power supply or a the power is interrupted.
If node reboots, the following error can be seen in the EMS log files Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert...If node reboots, the following error can be seen in the EMS log files Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(n4-nht-fas-c03-02), system_down because l2_watchdog_reset. Wed May 11 00:21:59 +0100 [NetApp: cf_hwassist: cf.hwassist.takeoverTrapRecv:notice]: hw_assist: Received takeover hw_assist alert from partner(n4-nht-fas-c03-02), system_down because reset_via_sp.
AutoSupport Message - Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-X]) ALERT. A proactive notification is sent by ONTAP once a critical amount of errors on a memory module has been ...AutoSupport Message - Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-X]) ALERT. A proactive notification is sent by ONTAP once a critical amount of errors on a memory module has been detected.