H610S: erroneous NVRAM error messages
Applies to
NetApp H610S storage node
Issue
This article addresses sporadic logging of NVRAM faults on H610S nodes, which often results in eviction of node's slice (metadata) drive
- The node logs a variation of one of the following NVRAM (NVDIMM) faults:
|
|
|
|
|
|
|
- The node's slice/metadata drive (drive 0) may be ejected, depending on error that is logged and Element OS version the node is running
If node is running | |
---|---|
Element 10.x | Slice drive will most likely not be ejected, depending on timing factors within Element |
Element 11.0 through 11.1 | Slice drive will be ejected, regardless of timing |
Element 11.3.0 | Slice drive may be ejected, depending on which of the above mentioned faults was experienced |
- NVRAM (NVDIMM) fault resolves on its own less than 5 minutes later
- If node's slice/metadata drive (drive 0) was ejected, it will not automatically re-add
Note: If these alerts are resolved, no further action from support is required