SF Series Node Hardware Fault: RTFI_HARDWARE_FAILURES RADIAN_TIME_TO_CHARGE during RTFI or timeToChargeCapacitors: {>150} in cluster UI
Applies to
- SF Series storage nodes
Issue
- In Storage cluster UI, a node fault:
nvramDeviceStatus
NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. warning={timeToChargeCapacitors: [>150] Seconds} error={derivedCapacitanceOfThePack: 0.000 F}
OR
- During RTFI:
There were 1 hardware related RTFI_HARDWARE_FAILURES
RADIAN_TIME_TO_CHARGE
Example screenshot during RTFI:
- If this occurs during RTFI, accept the message
Ignore errors and continue (ALT-F8 to display, ALT-F7 to return) (Yes,No)
- Finish the RTFI and add the node to the cluster, but do not add any drives
- Cluster UI should show a node fault similar to:
NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. error={derivedCapacitanceOfThePack: 0.000 F, timeToChargeCapacitors: 42949664 Seconds}