Issue

  • All SAN initiators report Partially Connected
  • In system Manager Single FC port from each node in 2 node HA pair has 0 MB/s  throughput
  • In fibre channel environment hundreds of Host logins (PLOGI) across all storage nodes seen in EMS logs
  • VMware hosts experience disconnections, all paths down (APD), permanent device loss (PDL)
  • All connection issues proceeded from a fabric registered state change notification (RSCN)
  • Missing/failed paths for one Storage Target HBA port once system is stable
VMware log Example:
esxcfg-mpath -b
vmhba2:C0:T6:L1 LUN:1 state:dead fc Adapter: Unavailable Target: Unavailable
vmhba2:C0:T3:L1 LUN:1 state:dead fc Adapter: Unavailable Target: Unavailable

less /var/run/log/vmkernel.log
lpfc_els_rcv_rscn:5945: 0:(0):0214 RSCN received Data:
lpfc_els_rcv_rscn:5955: 0:(0):5973 RSCN received event x0 : Address format x03 : DID x000000
lpfc_handle_status:5079: 0:(0):3271: FCP cmd x8a failed <1/6> sid , did , oxid x7a iotag x417 Invalid RPI Host Retry
NMP: nmp_ThrottleLogForDevice:3861: Cmd 0x8a (,) to dev "naa.xyz" on path "vmhba1:C0:Tx:L1" Failed:
 
NetApp:
bcomd: san.initiator.login.missing:notice]: Initiator "xyx" is not logged in to any LIFs on this node for Vserver "svm123", portset "". Access to LUNs might be disrupted if a failover occurs.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.