Skip to main content
If you missed the pre-registration for NetApp MS Azure AD B2C Go Live, when you log in, the new login prompt will offer the option to register. Please note that access to your NetApp data may take up to 1 hour. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 
NetApp Knowledge Base

FCP WQE error repeats during high latency system operation

Views:
75
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
san
Last Updated:

Applies to

  • Clustered Data ONTAP 8.3 and later
  • ONTAP 9.1
  • Emulex LPe32000 FCP target port

Issue

scsitarget.slifct.wqeError and fcp.io.status repeats from Emulex FCP target port(Emulex LPe32000 (LPe32002) rev. 12) during high latency system operation.
 
 
Example:
 
7/23/2021 04:05:48  FAS-01  DEBUG  scsitarget.slifct.wqeError: FC port 10a has a WQE processing failure of type SLI_IO_ABORT, command N/A, subtype x0, with status of 3 and an extended status x5 for NPIV port 3.
 
7/23/2021 04:05:48  FAS-01  DEBUG  fcp.io.status: STIO Adapter:10a IO WQE failure, Handle 0x6, S_ID: C70160, OX_ID: F56, Status 0x3 Ext_Status 0x5
 
7/23/2021 04:05:49  FAS-01  ERROR  wafl.cp.toolong: Aggregate aggr1 experienced a long CP.