Skip to main content
NetApp Knowledge Base

DualControllerHa_Alert for HA pair. Path to shelf missing on 1 node

Views:
225
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8080
  • ONTAP 9
  • DS4246

Issue

  • Shelf missing path to one node in an HA pair.
  • All disks still show connected to the node.
  • All other shelves in the stack are present with active paths to both nodes.
  • The shelf is present in the SAS Expander map but the path to the node is not present in the sysconfig -a output.

::>run -node sysconfig -a
<output snipped>
    slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
        Firmware rev:       XX.XX.XX.XX
        Base WWN:           5:00a098:XXXXXXX:XX
        Phy State:          [0] Enabled, 6.0 Gb/s
                            [1] Enabled, 6.0 Gb/s
                            [2] Enabled, 6.0 Gb/s
                            [3] Enabled, 6.0 Gb/s
        QSFP Vendor:        Amphenol        
        QSFP Part Number:   X6559-R6+A0     
        QSFP Type:          Passive Copper 5m ID:00
        QSFP Serial Number: XXXXXXXXXXXXXX
                00.0 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.1 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.2 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.3 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.4 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.5 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.6 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.7 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.8 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.9 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.10: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.11: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.12: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.13: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.14: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.15: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.16: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.17: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.18: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.19: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.20: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.21: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.22: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                00.23: NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                01.0 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                01.1 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                01.2 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                01.3 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
                01.4 : NETAPP   X316_SMKRE06TA07 NA01 5614.6GB 520B/sect (XXXXXXXX)
        << missing shelf 0 >>
        Shelf 1: DS4246  Firmware rev. IOM6 A: 0200  IOM6 B: 0200

::>run -node node-01 sasadmin expander_map
Expanders on channel 0a:
Level    1: WWN 500a098XXXXXXXXX, ID  0, Serial Number ' XXXXXXXXXXXXXXX', Product 'DS424IOM6       ', Rev '0200', Slot B
Level    2: WWN 500a098XXXXXXXXX, ID  1, Serial Number ' XXXXXXXXXXXXXXX', Product 'DS424IOM6       ', Rev '0200', Slot B

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.