Skip to main content
NetApp Knowledge Base

Both nodes report chassis temperature sensors invalid

Views:
121
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS9000
  • AFF A700
  • Fibre Channel Target Host Adapter Emulex LPe32000 (LPe32004)

Issue

  • Both nodes report the following sensors invalid which can be seen in the system sensors show command output from the Service Processor:
Chassis is Under Temp    invalid            --
Chassis is Over Temp     invalid            --
Thermal Shutdown         invalid            --
Temp Average Low         invalid            --
Temp Average High        invalid            --
  • The following HBA is installed in the affected slots:

sysconfig: slot 3 OK: X91135A: HBA,4-Port FCP Target 32Gb PCIe

slot 3: Fibre Channel Target Host Adapter 3a
(Emulex LPe32000 (LPe32004) rev. 12, <ONLINE>)

  • IO cards with the affected HBA installed will report invalid temperature readings although the card is present and healthy as indiated by the "FRU_AVAIL" output:
IO3 Aggr Temp            invalid            --
IO3 Avg Temp             invalid            --
FRU IO3                  invalid            --

IO3 INFO                                FRU_AVAIL
IO3_Status       | 0x0        | discrete   | Ready      | na        | na        | na        | na
IO3 Present                             PRESENT
IO3 Ready                                READY
IO3 Status               normal            57          --          --          --          --


IO11 Aggr Temp           invalid            --
IO11 Avg Temp            invalid            --
FRU IO11                 invalid            --

IO11 INFO                               FRU_AVAIL
IO11_Status      | 0x0        | discrete   | Ready      | na        | na        | na        | na
IO11 Present                            PRESENT
IO11 Ready                               READY
IO11 Status              normal            57          --          --          --          --

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • Was this article helpful?