AFF/FAS80x0 - Chassis fan failure alerts reported even after fan replacement

Views:
1,457
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS/AFF 80x0
  • AFF A800
  • Data ONTAP 8
  • ONTAP 9
  • SysFan or IOFan Failed

Issue

  • Multiple system fans failed.
  • Node Environmental Shutdown
  • EMS.log shows:

[node-n1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
[node-n1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F2 (failed)
[node-n1: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[node-n1:monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: Sysfan3 F2, Sysfan3 F1.

[node-n1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

  • This platform has 3 SysFans for each controller (6 in total)
    • If there is an IOXM installed, there will be 3 SysFans and 3 IOFans
    • SysFans are in front of the contoller
    • IOFans are in front of the IOXM
  • After swapping the SysFan with the error with a known working SysFan from another bay, the issue remains on the same bay.
  • If the issue is just with one SysFan, the other node should be up and running all the time. Do not use the partner node SysFans for testing.
  • Messages like the following can be found at SYSCONFIG -M :
!Chassis!021530002902!111-01459!E0!
!FAN1!021528004801!441-00037!D0!
!FAN2!021528004775!441-00037!D0!
!FAN3: Error reading FRU EEPROM
!FAN4!021528005758!441-00037!D0!
!FAN5!021528004271!441-00037!D0!
!FAN6!021528004776!441-00037!D0!
  • In the SP events :
Aug 12 00:02:08 (none) seld[550]:   FPGA event 21 : Fan Reset 3 asserted
Aug 12 00:02:09 (none) seld[550]:   FPGA event 21 : Fan Reset 3 de-asserted
Aug 12 00:02:15 (none) : [353 INFO]FanDaemon: Fan module 3 was reset (waiting some time before accessing)
Aug 12 00:02:20 (none) : [353 INFO]FanDaemon: Fan module 3 reset should be complete (will attempt access next cycle)
Aug 12 00:02:26 (none) : [353 WARNING][Porting/platform/PDKFan.c:1661]FanDaemon: Failure to read FanModuleData from fan module 3
Aug 12 00:02:26 (none) : [353 WARNING][Porting/platform/PDKFan.c:1676]FanDaemon: Reset Fan Module 3
Aug 12 00:02:26 (none) : [353 INFO]Fan Module 3 Reset
  • Errors remain on the same SysFan bay after swapping with a known good fan.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.