env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F1 (failed) Thu Jun 24 11:18:36 MSK [toaster1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan cont...env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F1 (failed) Thu Jun 24 11:18:36 MSK [toaster1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F1 (failed) Thu Jun 24 11:18:37 MSK [toaster1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F2 (failed)
Due to simultaneous sysfan issues, both nodes went down almost at the same time and could not be rebooted Record 697: Wed Jul 10 03:43:55.912019 2024 [Agent.notice]: 708.941: 14 : Attention LED (at Mi...Due to simultaneous sysfan issues, both nodes went down almost at the same time and could not be rebooted Record 697: Wed Jul 10 03:43:55.912019 2024 [Agent.notice]: 708.941: 14 : Attention LED (at Midplane) de-asserted Record 698: Wed Jul 10 03:44:38.784222 2024 [Agent.notice]: 581.167: 14 : Attention LED (at Midplane) asserted Record 700: Wed Jul 10 03:45:42.072589 2024 [Agent.notice]: 869.523: 14 : Attention LED (at Midplane) asserted
[node-n1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F2 (failed) After swapping the SysFan with the error with a known working SysFan from another ...[node-n1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F2 (failed) After swapping the SysFan with the error with a known working SysFan from another bay, the issue remains on the same bay. If the issue is just with one SysFan, the other node should be up and running all the time. Errors remain on the same SysFan bay after swapping with a known good fan.