In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

SolidFire/HCI error message after replacing an SSD: drive is using unsupported firmware version

Views:
957
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

  • NetApp SolidFire storage nodes
  • NetApp HCI storage nodes
  • NetApp Element software

Issue

The replacement drive has a version of firmware different than the expected firmware for the version of Element software that the node is running

Note: The same error message will be logged whether the firmware version is higher or lower than the expected version

Example 1: A drive with higher firmware is inserted into a node running an older version of NetApp Element:

  • Element software will not downgrade the firmware on that drive
  • A hardwareConfigMismatch cluster fault similar to the following will be logged:

The drive in slot 3 should be using firmware version EDA5202Q, but is using unsupported version EDA5302Q

Example 2: A drive with lower firmware is inserted into a node running a newer version of NetApp Element:

  • If the cluster is running Element software 11.x or below, Element software will not attempt to upgrade the firmware on the drive
  • If the cluster is running Element software 12.x or above, Element software will attempt to upgrade the firmware on the drive
  • In some instances, the attempt to update the drive firmware may fail, resulting in the following events:

driveEvent    Attempting to flash drive firmware.
driveEvent    Failed to flash drive firmware.
platformHardwareEvent    Hardware fault detected

  • A hardwareConfigMismatch cluster fault similar to the following will be logged:

The drive in slot 6 should be using firmware version EDA5302Q, but is using unsupported version EDA5202Q

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support