In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

AutoSupport Message: NodeHardwareFault

Views:
393
Visibility:
Public
Votes:
1
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

  • NetApp Element software
  • SolidFire AFA
  • NetApp HCI
  • NetApp SF-series
  • NetApp H-series

Issue

This article describes various alert types generated by NetApp storage clusters running Element Software, with corresponding troubleshooting references.

Error Code Error Details Severity Component
memoryUsageThreshold System memory is very low. Adding additional nodes or manually purging deleted volumes may help reduce memory usage. Error Memory
memoryUsageThreshold System memory is low. Adding additional nodes or manually purging deleted volumes may help reduce memory usage. Warning Memory
powerSupplyError Power supply PS2 input missing or out of range. Warning Power Supply
powerSupplyError Power supply PS1 input missing or out of range. Warning Power Supply
hardwareConfigMismatch The drive in slot <x> should be using firmware version <y>, but is using unsupported version <z> Warning Firmware (NIC)
nodeHardwareFault NETWORK_FIRMWARE_VERSION_ETH0 should be == 7.10.18-solidfire-5f3ccbc781d53 but is FFV7.10.18 bc 7.10.11 Warning Firmware (NIC)
nodeHardwareFault "Hardware fault ID 826 text=NETWORK_FIRMWARE_VERSION_ETH2 should be == 3.2d 0x80000b4b 1.1767.0 but is 3.2d 0x80000b4b 1.1681.0" Warning Firmware (NIC)
hardwareConfigMismatch Incorrect Block drive size (1.01GB)/(0.00) for the drive in slot x for this node type - expected xx Warning Drive (Hardware)
tempSensor Temperature sensor Inlet Temp is over temperature. Warning Temperature Sensor
hardwareConfigMismatch

Incorrect bios setting "CPU_CORES_01" should be == <x>but is <y>

Warning BIOS Settings
hardwareConfigMismatch Parse failure in /var/log/sf-bios.info should be == false but is true Warning Hardware Configuration

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support