In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NetApp KCS Award

NetApp Knowledge Base

MetroCluster disk ownership recovery - diskHasWrongInfo

Views:
238
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster
  • ONTAP 9
  • ONTAP 8.3.x
  • ATTO 7500 FibreBridge with Firmware lower than 2.77

Issue

  • SyncMirror Plex failures may be reported
  • Multiple disk failures reported
  • One or more nodes may have dropped due to disk reservation errors

Disk ownership errors will be reported in EMS logs:
[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L14 (S/N S2GUNCAH207559) has ownership information for disk MMP1-FCSW-2:3.126L16 (S/N S2GUNCAH207629) on it.
[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L4 (S/N S2GUNCAH206819) has ownership information for disk MMP1-FCSW-2:3.126L3 (S/N S2GUNCAH206838) on it.
[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L3 (S/N S2GUNCAH206838) has ownership information for disk MMP1-FCSW-2:3.126L7 (S/N S2GUNCAH206808) on it.
[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L5 (S/N S2GUNCAH206850) has ownership information for disk MMP1-FCSW-2:3.126L9 (S/N S2GUNCAH206836) on it.
[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L11 (S/N S2GUNCAH207587) has ownership information for disk MMP1-FCSW-2:3.126L20 (S/N S2GUNCAH207628) on it.

  • Bridge logs may report:

dsbridge_log_FB7500N101924.3:7F6664 14:54:43 09/21/16 INFO SAS IOP firmware fault, code 0000283E
dsbridge_log_FB7500N101924.3:806E5C 12:28:36 09/22/16 INFO SAS IOP firmware fault, code 0000283E

  • The issue can occur following a power cycle of an ATTO 7500N
  • Can occur if cabling changes are made behind an ATTO 7500N without respecting the debounce time
  • Can occur after  the FibreBridge reporting 88/05/12 error handling on the ATTO bridge

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support