Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 12 results
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_recover_a_failed_System_Volume_from_an_nvfailed_state
      As part of error handling during MetroCluster switchover operations, a volume can end in an nvfailed state. This article covers on how to recover a system volume like ONTAP's Metadata Volumes (MDV) fr...As part of error handling during MetroCluster switchover operations, a volume can end in an nvfailed state. This article covers on how to recover a system volume like ONTAP's Metadata Volumes (MDV) from this situation. The instructions for restoring access to data volumes can be found here. To identify if a volume is in an nvfailed state, run the following command: In the above example, no volume is in nvfailed state. In the above example, one volume is in the nvfailed state.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_check_network_reachablity_in_a_MetroCluster_environment
      This article explains how to check the lif reachablity in a MetroCluster configuration. The primary factor used to determine suitable a port to be used for placement is reachability, as determined by ...This article explains how to check the lif reachablity in a MetroCluster configuration. The primary factor used to determine suitable a port to be used for placement is reachability, as determined by an ARP broadcast. The broadcast is triggered from each connected port on the site with the -mc vserver, the destination for the LIF in event of switchover. If the port already hosts its own LIF in the same subnet a broadcast is not sent.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/MetroCluster_disk_ownership_recovery_-_diskHasWrongInfo
      [cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L4 (S/N S2GUNCAH206819) has ownership information for disk MMP1-FCSW-2:3.126L3 (S/N S2GUNCAH206838) on it. [cluster01_1:...[cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L4 (S/N S2GUNCAH206819) has ownership information for disk MMP1-FCSW-2:3.126L3 (S/N S2GUNCAH206838) on it. [cluster01_1: sanown_io: diskown.diskHasWrongInfo:error]: Disk MMP1-FCSW-2:3.126L3 (S/N S2GUNCAH206838) has ownership information for disk MMP1-FCSW-2:3.126L7 (S/N S2GUNCAH206808) on it.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_remove_a_DR-Group_from_a_MetroCluster
      Applies to ONTAP 9 MetroCluster 8 node Remove DR Group Scale down Description This article describes how to scale down a MetroCluster by one DR-Group. This article describes how to scale a MetroCluste...Applies to ONTAP 9 MetroCluster 8 node Remove DR Group Scale down Description This article describes how to scale down a MetroCluster by one DR-Group. This article describes how to scale a MetroCluster from 8 to 4 nodes
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_reset_to_default_the_username_and_password_of_the_FibreBridge
      Applies to ATTO 6500N FibreBridge ATTO 7500N FibreBridge ATTO 7600N FibreBridge Description This article describes the procedure to recover or reset (to default) the user and password of the FibreBrid...Applies to ATTO 6500N FibreBridge ATTO 7500N FibreBridge ATTO 7600N FibreBridge Description This article describes the procedure to recover or reset (to default) the user and password of the FibreBridge if the password has been lost or is not working any more. FC-SAS Bridge root password lost
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_to_increase_size_of_ONTAP_CIFS_auditing_MDV_staging_volume
      Applies to ONTAP 9 Description The CIFS auditing relies on the Consolidation of data stored temporarily in audit staging volumes. If these volumes fill prior to the completion of the audit consolidati...Applies to ONTAP 9 Description The CIFS auditing relies on the Consolidation of data stored temporarily in audit staging volumes. If these volumes fill prior to the completion of the audit consolidation process, audit consolidation can fail. Due to this, The CIFS access will experience disruption if audit-guarantee is enabled. EMS.Log:[node01: AuditWorkerThread01: adt.stgvol.nospace:EMERGENCY]: Audit subsystem internal error: Staging volume MDV_aud_0ade1c55884e44ad80ca123eff96b2ac is full.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_interpret_the_ATTO_FibreBridge_specific_error_codes
      Applies to ATTO 6500N ATTO 7500N ATTO 7600N 0x0B 0x88 Sense code Description The below is a list of all check conditions that are specific to the ATTO FibreBridge.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_collect_log_files_from_an_ATTO_7500N_7600N_in_9.3_and_later
      Applies to ONTAP 9.3+ MetroCluster ATTO 7500N ATTO 7600N Description This article describes how to collect log files from an ATTO 7500N/7600N FibreBridge in 9.3 and later. ONTAP 9.3 and later does alr...Applies to ONTAP 9.3+ MetroCluster ATTO 7500N ATTO 7600N Description This article describes how to collect log files from an ATTO 7500N/7600N FibreBridge in 9.3 and later. ONTAP 9.3 and later does already collect the bridge log files periodically. Detailed configuration dumps need to be collected manually, basic configuration data is available through ONTAP health monitoring.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Stale_entries_displayed_after_replacing_ATTO_FibreBridge
      ATTO FibreBridge If an ATTO FibreBridge is replaced, storage bridge show displays the stale entries If a user attempts to remove the stale entries by running storage bridge remove , the following erro...ATTO FibreBridge If an ATTO FibreBridge is replaced, storage bridge show displays the stale entries If a user attempts to remove the stale entries by running storage bridge remove , the following error is displayed: Failed to remove bridge from monitoring on node "mcc-siteA-01" in cluster "mcc-siteA". Reason: entry doesn't exist. Bridge Symbolic Name Monitored Status Vendor Model Bridge WWN "" mccfb02 false - Atto FibreBridge 6500N 200000108affeaffe
    • https://kb.netapp.com/on-prem/E-Series/Hardware-KBs/What_are_the_E_Series_Controller_Shell_Passwords
      Applies to All E-Series controller platforms All E-Series firmware revisions Description To access the shell of a legacy LSI system or a current NetApp E-series system, you must have the correct user ...Applies to All E-Series controller platforms All E-Series firmware revisions Description To access the shell of a legacy LSI system or a current NetApp E-series system, you must have the correct user login and password.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_troubleshoot_MetroCluster_LIF_placement_using_network_traces
      Applies to MetroCluster ONTAP 9 Description LIF placement between clusters in MetroCluster is not decided on a 1:1 naming basis. The primary factor used to determine suitable a port to be used for pla...Applies to MetroCluster ONTAP 9 Description LIF placement between clusters in MetroCluster is not decided on a 1:1 naming basis. The primary factor used to determine suitable a port to be used for placement is reachability, as determined by an ARP broadcast.