Skip to main content
NetApp Knowledge Base

Why does the BES-53248 switch present 2 MAC addresses at its service port?

Views:
193
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Broadcom BES-53248 switch

Answer

The second MAC and eventually a DHCP-assigned IP belong to the switch BMC (Baseboard Management Controller).
 
  • The following output provide more information regarding the BMC:
 
(switch1) #show environment

Baseboard Management Controller Present........ Yes
Baseboard Management Controller MAC Address.... C0:18:51:59:13:C9
Baseboard Management Controller IP Address..... 10.10.10.10
...
 
  • The following outputs provide more information regarding the service port settings:
 

(switch1)#show serviceport

Interface Status............................... Up
IP Address..................................... 10.10.10.11
Subnet Mask.................................... 255.255.255.0
Default Gateway................................ 10.10.10.1
...
Burned In MAC Address.......................... B4:A9:FC:A9:DF:68

(switch1)#show running-config

...

hostname "switch1"
serviceport protocol none
serviceport ip 10.10.10.11 255.255.255.0 10.10.10.1
...

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.