Skip to main content
NetApp Knowledge Base

Single NVMe disks missing in one node of a Metrocluster

Views:
332
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
MetroCluster
Last Updated:

Applies to

  • AFF A800
  • NVMe drive
  • Metrocluster IP

Issue

  • NVMe disk replaced after a failure
  • The internal shelf disk is not detected on a single node/path
  • The HA partner node can see the drive. Example:

 ::> disk show 2.0.19
                      Disk: 2.0.19
          Container Type: unknown
              Owner/Home: node_name1 / node_name1
                 DR Home: -
      Stack ID/Shelf/Bay: 2  / 0  / 19
                     LUN: 0
                   Array: N/A
                  Vendor: NETAPP
                   Model: X4014S173315TNTE
           Serial Number: SxxSNExR123456
                     UID: 36305330:52402518:00253845:00000003:00000000:00000000:00000000:00000000:00000000:00000000
                     BPS: 4160
           Physical Size: 13.97TB
                Position: present
  Checksum Compatibility: block
               Aggregate: -
                    Plex: -
                   Paths:
        LUN        Initiator Side Target Side                                       Link
Controller         Initiator ID   Switch Port Switch Port Acc Use  Target Port      TPGN  Speed  I/O KB/s IOPS
------------------ --------  ---- ----------- ----------- --- ---  ---------------- ----  ------ -------- ------------
node_name2         0n        0    N/A         N/A         AO  INU  0d200000cdab0000 88   0 Gb/S  0        0
                  Errors:  -

  • The other nodes in the other side of the Metrocluster IP can see the drive. Example:

::> disk show 2.0.19
                     Disk: 2.0.19
           Container Type: unknown
               Owner/Home: node_name1 / node_name1
                  DR Home: -
       Stack ID/Shelf/Bay: 2  / 0  / 19
                      LUN: 0
                    Array: N/A
                   Vendor: NETAPP
                    Model: X4014S173315TNTE
            Serial Number: SxxSNExR123456
                      UID: 12345678:12345678:12345678:12345678:00000000:00000000:00000000:00000000:00000000:00000000
                      BPS: 4160
            Physical Size: 13.97TB
                 Position: present
   Checksum Compatibility: block
                Aggregate: -
                     Plex: -
                    Paths:
        LUN        Initiator Side Target Side                                       Link
Controller         Initiator ID   Switch Port Switch Port Acc Use  Target Port      TPGN  Speed  I/O KB/s IOPS
------------------ --------- ---- ----------- ----------- --- ---  ---------------- ----  ------ -------- ------------
node_name1         0v        26   N/A         N/A         AO  RDY  3433232202000000 93    - Gb/S 0        0
node_name1         0m        26   N/A         N/A         AO  INU  2122121101000000 1     - Gb/S 0        0
node_name2         0v        26   N/A         N/A         AO  INU  3133232202000000 90    - Gb/S 0        0
node_name2         0m        26   N/A         N/A         AO  RDY  2422121101000000 4     - Gb/S 0        0

                   Errors: -

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.