Single PHY disabled on IOM
Applies to
- Fabric MetroCluster
- ONTAP 9
- DS224C
- ATTO FB7600N
Issue
A single PHY is reported as 'DIS/INVWD' (disabled)
Example:
::> node run -node ClusterA-01 -command "storage show shelf"
...
Shelf name: SiteA_SW1:11.shelf15 Shelf id: 15 Channel: SiteA_SW1-1_SAN2:11 Module: B Shelf UID: 00:00:00:00:00:00:00:00 Shelf S/N: 000000000000000 Term switch: N/A Shelf state: ONLINE Module state: OK Partial Path Link Invalid Running Loss Phy CRC Phy Disk Port Timeout Rate DWord Disparity Dword Reset Error Change Id State Value (ms) (Gb/s) Count Count Count Problem Count Count -------------------------------------------------------------------------------------------- ... [HST8] OK 7 12.0 0 0 0 0 0 3 [HST9] OK 7 12.0 0 0 0 0 0 3 [HST10] DIS/INVWD 7 NA 891967 889948 0 0 0 6 [HST11] OK 7 12.0 0 0 0 0 0 3
...