Applies to

FAS2750

Answer

  • When one PSU located in external shelf get powerred off for the first time, below EMS event are expected to see in both nodes:

Thu Aug 18 13:28:59 +0900 [Nodename: dsa_worker2: ses.status.psWarning:error]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power warning for Power supply 1: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: ses.status.psError:alert]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power error for Power supply 1: critical status; AC Fail. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:29:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:29:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • If same PSU get powerred off within 6 hours, ses.status.psWarning and ses.status.psError will be suppressed:

Thu Aug 18 13:43:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:43:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:43:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • It is an expected behavior for external shelf, same warning message from same alerting resource are inhibited within 6 hours.

Additional Information

  • PSU status can be confirmed via system node run -node * -command environment status
  • With PSU located in internal shelf(chassis) failed, those two EMS events will never be supressed.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.