Skip to main content
NetApp Knowledge Base

Why does Auto Giveback become true automatically after chassis replacement?

Views:
189
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

ONTAP 9

Answer

  • Enabling the HA configuration command "cluster ha modify -configured true" is described in the Chassis Replacement Guide.
  • If the HA setting is true, "auto givaback" and "storage failover" are automatically enabled.

Additional Information

The warning of command cluster ha modify -configured true indicates the change for the auto giveback is required.

::*> cluster ha modify -configured true

Warning: High Availability (HA) configuration for cluster services requires
         that both SFO storage failover and SFO auto-giveback be enabled. These
         actions will be performed if necessary.
Do you want to continue? {y|n}:

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.