Skip to main content
NetApp Knowledge Base

Controller shut down due to low NVRAM battery

Views:
812
Visibility:
Public
Votes:
2
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • AFF / FAS

Issue

  • The new controllers have just been installed
  • When booting ONTAP, the following message appears on CLI

WARNING:  The battery is unfit to retain data during a power
          outage.  This is likely because the battery is
          discharged but could be due to other temporary
          conditions.
          When the battery is ready, the boot process will
          complete and services will be engaged.
          To override this delay, press 'c' followed by 'Enter'

  • The warning is ignored and ONTAP is forced to boot

CAUTION: Using this appliance without NVRAM
         battery backup coupled with a power
         failure condition CAN CAUSE DATA LOSS.

Are you sure you want to continue (y or n)? y

Proceeding without NVRAM battery backup.

  • Controllers halt with the following message

[node-01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery remain capacity critical)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.