- Multiple single-disk errors trigger that disk offline for recovery purposes. Example:
[node_name: config_thread: raid.disk.assign.offline_ref:debug]: aggregate /data_aggregate/plex0/rg0/0a.01.1 assigned as an offline reference storage for /data_aggregate/plex0/rg0/0a.01.5.
[node_name: config_thread: raid.disk.assign.offline_ref:debug]: aggregate /data_aggregate/plex0/rg0/0a.01.3 assigned as an offline reference storage for /data_aggregate/plex0/rg0/0a.01.5.
[node_name: config_thread: raid.rg.degraded:notice]: : Raid group /data_aggregate/plex0/rg0 is degraded
[node_name: config_thread: raid.disk.offline:notice]: Marking Disk /data_aggregate/plex0/rg0/0a.01.5 Shelf 1 Bay 5 [NETAPP X123_ABCDE1F2G34 NA02] S/N [12345678] UID [00000000:::::::::00000000] offline.
- RAID group and aggregate are degraded during the offline disk status. Example:
Aggregate data_aggregate (online, raid_dp, degraded) (block checksums)
Plex /data_aggregate/plex0 (online, normal, active, pool0)
RAID group /LF_FAS8200_801A_data_aggregate/plex0/rg0 (degraded, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0a.01.1 0a 1 1 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
parity 0a.01.3 0a 1 3 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
data 0a.01.5 0a 1 5 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768 (offline)
data 0a.01.7 0a 1 7 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
- When ONTAP recovers the disk, the RAID group and aggregate change back to normal status. Example:
[node_name: config_thread: raid.disk.online:notice]: Onlining Disk /data_aggregate/plex0/rg0/0a.01.5 Shelf 1 Bay 5 [NETAPP X123_ABCDE1F2G34 NA02] S/N [12345678] UID [00000000:::::::::00000000].
[node_name: config_thread: raid.rg.optrecons.start:debug]: /data_aggregate/plex0/rg0: starting optimized reconstruction, using disk 0a.01.5, disk block 5248
[node_name: config_thread: raid.rg.normal:notice]: : raid group /data_aggregate/plex0/rg0 is in normal state.