Issue

  • ESXi host continuously getting below alert on VMware side.

Alarm alarm.StorageConnectivityAlarm on Host hostabc.xxx.com
because Path redundancy to storage device naa.600a098xxxxxx46c3f515xxxxxxxx degraded. Path vmhba2:C0:xx:xx0 is down. Affected datastores: xxx-NetApp-xyz..
Alarm name  alarm.StorageConnectivityAlarm
Description alarm.StorageConnectivityAlarm
Target      Host hostabc.xxx.com
Triggered time    04/10/2023 10:40:57 AM

  • FC LUNs are mapped to these hosts from NetApp storage.
  • There are no disruptions seen at host side due to these alerts.
  • Alerts are being generated very frequently at host side almost 3 hours or so.
  • LUNs at storage side are online, mapped and no errors observed in EMS logs during the issue timestamp.
  • FC ports are all up and Rx, Tx values are in optimal range.
  • Brocade switch log analysis indicated an issue with port between switch & NetApp storage.
  • Switchshow reports the port as online

/fabos/bin/switchshow :
Index Port Address  Media Speed   State       Proto
==================================================
   9   9   020900   id    N8   Online      FC  F-Port  1 N Port + 1 NPIV public 

  • Porterrshow indicates multiple media errors are reported for the port.

/fabos/cliexec/porterrshow :
          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                  tx    rx     err    err
  9:    3.4g   1.5g  39.4k  30.9m  30.5m   0     11.3k 454.4k   2.1m  79.2k 206      0      2.4k   0      0      0      0    264.1m   0   

  • Under sfpshow it is observed that Rx value is not in optimal range whereas Tx value is in optimal range.

Port  9:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
[..]
Vendor Name: HP-F     BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   QK724A          
[..]
RX Power:    -12.1   dBm (61.0 uW) 
TX Power:    -3.2    dBm (483.8 uW) 

 

  • Portstatsshow indicates that port encountered multiple issues.

portstatsshow 9
[..]     
fec_cor_detected        0                   Count of blocks that were corrected by FEC
fec_uncor_detected      0                   Count of blocks that were left uncorrected by FEC
er_enc_in               39648               Encoding errors inside of frames
er_crc                  30968151            Frames with CRC errors
er_trunc                0                   Frames shorter than minimum
er_toolong              11379               Frames longer than maximum
er_bad_eof              454430              Frames with bad end-of-frame
er_enc_out              2172705             Encoding error outside of frames
er_bad_os               3801509             Invalid ordered set
er_pcs_blk              264192520           PCS block errors
er_rx_c3_timeout        0                   Class 3 receive frames discarded due to timeout
er_tx_c3_timeout        0                   Class 3 transmit frames discarded due to timeout
er_unroutable           20153               Frames that are unroutable
er_unreachable          0                   Frames with unreachable destination
er_other_discard        79253               Other discards
er_type1_miss           0                   frames with FTB type 1 miss
er_type2_miss           0                   frames with FTB type 2 miss
er_type6_miss           0                   frames with FTB type 6 miss
er_zone_miss            71                  frames with hard zoning miss
er_lun_zone_miss        0                   frames with LUN zoning miss
er_crc_good_eof         30502349            Crc error with good eof
er_inv_arb              0                   Invalid ARB
er_single_credit_loss   0                   Single vcrdy/frame loss on link
er_multi_credit_loss    0                   Multiple vcrdy/frame loss on link
other_credit_loss       0                   Link timeout/complete credit loss
phy_stats_clear_ts      06-23-2022 UTC Thu 14:06:23      Timestamp of phy_port stats clear
lgc_stats_clear_ts      06-23-2022 UTC Thu 14:06:23      Timestamp of lgc_port stats clear

 

  • Fabriclog indicates the port flapped multiple times.

Switch 0; Mon Apr 10 09:34:46 2023 GMT (GMT+0:00)
09:34:56.224522 SCN Port Offline;rsn=0x2,g=0xc0             D0,P0  D0,P0  9     NA    
09:34:56.224540 *Removing all nodes from port               D0,P0  D0,P0  9     NA    
09:35:08.666250 SCN LR_PORT(0);g=0xc0                       D0,P0  D0,P0  9     NA    
09:35:08.671197 SCN Port Online; g=0xc0,isolated=0          D0,P0  D0,P1  9     NA    
09:35:08.671407 Port Elp engaged                            D0,P1  D0,P0  9     NA    
[..]
13:00:36.370320 SCN Port Online; g=0xc4,isolated=0          D0,P0  D0,P1  9     NA    
13:00:36.370531 Port Elp engaged                            D0,P1  D0,P0  9     NA    
13:00:36.370601 *Removing all nodes from port               D0,P0  D0,P0  9     NA    
13:00:36.370803 SCN Port F_PORT                             D0,P1  D0,P0  9     NA    
13:11:22.396502 SCN LR_PORT(0);g=0xc4 LR_IN                 D0,P0  D0,P0  9     NA    

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.