Skip to main content
NetApp Knowledge Base

New/Migrated LUN are not visible on host due to SLM/portset

Views:
193
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

Applies to

ONTAP 9

Issue

  • Unable to connect to new LUN
  • After volume migartion host not able to access the LUN
  • LUN is online, mapped and on the expected node as indicated in System Manager or on CLI

    Example:

cluster1::> lun show -path /vol/vol_linux/lun1 -fields vserver,path,state,mapped,node
vserver   path                state  mapped node
--------- ------------------- ------ ------ -----------
svm_linux /vol/vol_linux/lun1 online mapped cluster1-03

  • igroup has SLM and portset set

    Example:

cluster1::> lun mapping show -path /vol/vol_linux/lun1  -fields vserver,path,igroup,portset,reporting-nodes
vserver   path                igroup      portset reporting-nodes
--------- ------------------- ----------- ------- -----------------------
svm_linux /vol/vol_linux/lun1 linux_iscsi test    cluster1-03,cluster1-04

 

  • portset contains LIFs

    Example:

cluster1::> portset show
Vserver   Portset      Protocol Port Names              Igroups
--------- ------------ -------- ----------------------- ------------
svm_linux test         mixed    iscsi_1-1, iscsi_1-2, iscsi_2-1, iscsi_2-2
                                                        linux_iscsi

 

  • LIFs are not on the same nodes that are used for SLM (reporting-nodes)

    Example:

     
    cluster1::> net int show -vserver svm_linux -data-protocol iscsi  -fields lif,curr-node
      (network interface show)
    vserver   lif       curr-node
    --------- --------- -----------
    svm_linux iscsi_1-1 cluster1-01
    svm_linux iscsi_1-2 cluster1-01
    svm_linux iscsi_2-1 cluster1-02
    svm_linux iscsi_2-2 cluster1-02

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.