SAS Controller reset errors on ATTO bridges
- Views:
- 214
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster
- Last Updated:
- 9/22/2023, 9:27:00 AM
Applies to
- ONTAP 9
- ATTO bridge 7600
Issue
Similar errors can be seen in the ATTO bridge event log:
01203E 07:41:17 01/12/21 INFO SAS IOP firmware fault, code 0000283E
01203F 07:41:17 01/12/21 INFO SAS IBDB-L = 00000000
012040 07:41:17 01/12/21 INFO SAS OBDB-L = 00000000
012041 07:41:17 01/12/21 INFO SAS OBDBM-L = 00000000
012042 07:41:17 01/12/21 INFO SAS Scr0 = 40002000
012043 07:41:17 01/12/21 INFO SAS Scr1 = 0000283E
012044 07:41:17 01/12/21 INFO SAS Scr2 = 00000800
012045 07:41:17 01/12/21 INFO SAS Scr3 = 5C0050D2
012046 07:41:17 01/12/21 INFO SAS Scr Rsvd0 = 00000000
012047 07:41:17 01/12/21 INFO SAS Scr Rsvd0 = 00000000
012048 07:41:17 01/12/21 INFO SAS firmware is being reset (0x180000FA)
012049 07:41:17 01/12/21 WARN Resetting SAS Controller.