"Drive has failed SMART health check" alert in Element Software
- Views:
- 1,257
- Visibility:
- Public
- Votes:
- 0
- Category:
- element-software
- Specialty:
- solidfire
- Last Updated:
- 9/17/2024, 1:38:38 PM
Applies to
- NetApp Element Software
- NetApp SolidFire SF-Series
- NetApp H-series
Issue
Errors in NetApp SolidFire Active IQ:
- Error Code:
driveHealthFault
- Details:
Drive with serial: <xxxxxxxxxx> in slot: <y> has failed SMART overall health check
- Example:
Drive with serial: S3SZABCD01234 in slot: 3 has failed SMART overall health check
- Example:
- Error Code:
driveHealthFault
- Details:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates Non-volatile capacitance is failing, raw critical bytes 0-11: 0x10 0x2a 0x01 0x64 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- Example:
Drive with serial: S3T2NX0M305154 in slot: 7, Drive should be replaced. SMART data indicates Non-volatile capacitance is failing, raw critical bytes 0-11: 0x10 0x2a 0x01 0x64 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- Example:
- Error Code:
driveHealthFault
- Details:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates health failed, raw critical bytes 0-11: 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- Example:
Drive with serial: S2TVNB0KA04565 in slot: 1, Drive should be replaced. SMART data indicates health failed, raw critical bytes 0-11: 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
- Example:
- Error Code:
driveHealthFault
- Details:
Drive with serial: <xxxxxxxxxx> in slot: <y>, Drive should be replaced. SMART data indicates it is read only, raw critical bytes 0-11: 0x08 0x31 0x01 0x5e 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00"
- Example:
Drive with serial: S438NA0N609921 in slot: 0, Drive should be replaced. SMART data indicates it is read only, raw critical bytes 0-11: 0x08 0x31 0x01 0x5e 0x0a 0x00 0x00 0x00 0x00 0x00 0x00 0x00"
- Example:
- Error Code:
driveFailed
- Details:
1 drive(s) with state: "SmartHealthFailed" driveID: xx
. - Details:
1 drive(s) with state: "NvmeReadOnly" driveID: xx.