Skip to main content
NetApp Knowledge Base

ONTAPClusterCreateTimedOut: ONTAP cluster create timed out

Views:
299
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
ontapselect
Last Updated:

Applies to

  • NetApp ONTAP Select (OTS) HA
  • NetApp ONTAP Select Deploy
  • CISCO
  • VMWare
  • Remote Branch Office (ROBO)
  • NAT configured in-between Deploy and OTS

Issue

  • ROBO deploy of OTS HA fails to multiple GEOs with the same error:

evtype='ClusterDeployFailed', category='cluster', level='Error', detail='ONTAPClusterCreateTimedOut: ONTAP cluster create timed out. Not all nodes successfully joined cluster "cluster01"

  • In the /opt/netapp/log/sdotadmin_server.log we see that we are getting timeouts when running cluster-add-node-status-get-iter API. The cluster is created successfully but the node join op looks to be failing:

2021-09-21 18:09:55,560|ERROR| 1474|34586|logger.py|132|ZAPI.py|89:retry| invoke: failed. Reason: timeout('timed out')
2021-09-21 18:09:55,560|DEBUG| 1474|34586|logger.py|132|ZAPI.py|241:invoke| 
API: "cluster-add-node-status-get-iter"
User: "admin"
Request:
<suppressed/>
Response:
<suppressed/>
2021-09-21 18:09:55,561|ERROR| 1474|34586|logger.py|132|ClusterZapis.py|286:z_get_cluster_add_node_status| Cluster [cluster01-01]: cluster-add-node-status zapi exception: [timeout('timed out')]

 

  • Pinging the Deploy IP from the OTS cluster-mgmt LIF works but not vice versa
  • When moving the cluster-mgmt LIF to another port (e0b) its IP can be pinged, but when moving it back to the default port (e0a) Ping will fail again.
  • Both Node mgmt LIF`s can be Pinged from Deploy CLI.
  • When shutting down the first nodes (where the cluster-mgmt LIF is home) node-mgmt LIF, the cluster-mgmt LIF is pingable.
  • When bringing the node-mgmt LIF online again, nothing changes in terms of the cluster-mgmt LIFs reachability, but the node-mgmt LIF is now no longer pingable.
  • When shutting down the cluster-mgmt LIF, node-mgmt LIF is reachable again.
  • When bringing the cluster-mgmt LIF back online again, it cannot be pinged or accessed, as before.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.