Skip to main content
NetApp Knowledge Base

METROCLUSTER SWITCHOVER FAILED - AutoSupport Message

Views:
800
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster
  • ONTAP 9
  • Switchover Failed
  • callhome.mcc.switchover.failed:EMERGENCY
    

Event Summary

This message occurs when a metrocluster switchover operation has failed. The failure could be partial or complete.

Validate

Event Log

event log show -event *switchover*

Command Line:

Run the following command on the cluster that attempted to perform the switchover operation.

metrocluster operation show

Operation: switchover
State: failed
Start Time: xxx
End Time: xxx
Errors: Failed to validate the node and cluster components before the switchover operation.
xxx(non-overridable veto): <Failure reason>

Resolution

  1. Verify the current state of the metrocluster

metrocluster node show

  1. Check if vservers are online:

vserver show

  1. Follow the recovery steps described in the metrocluster operation show output.
  2. Please contact NetApp Technical Support or log into the NetApp Support Site to create a case. Reference this article for further assistance.

Additional Information

Note: The metrocluster operation show output will only report on the last metrocluster operation. If a subsequent metrocluster operation has run since the switchover failure the output will not be relevant to the failure.

To get further details on a previous metrocluster operation:

  1. Run the metrocluster operation history show command to see all previous metrocluster operations:

metrocluster operation history show -fields operation,start-time,state,operation-uuid

  1. From the output, identify the operation-uuid of the failed or partially failed operation:

ClusterA::> metrocluster operation history show -fields operation,start-time,state,operation-uuid
operation-uuid                       operation           start-time         state
------------------------------------ ------------------- ------------------ ----------
b6fe95a4-dc12-11ec-881e-00a0985bd305 switchover-simulate mm/dd/yyyy hh:mm:ss successful
bffaf8b3-b9a4-11ec-881e-00a0985bd305 switchover-simulate mm/dd/yyyy hh:mm:ss successful
d719de7e-5a23-11ea-93d9-00a0985bd305 switchover          mm/dd/yyyy hh:mm:ss failed
2f258258-59b4-11e9-b2d2-00a0985bd305 switchover          mm/dd/yyyy hh:mm:ss completed-with-manual-recovery-needed

  1. Run the metrocluster operation history show command with the identified operation uuid:

metrocluster operation history show -operation-uuid <operation-uuid>

ClusterA::> metrocluster operation history show -operation-uuid d719de7e-5a23-11ea-93d9-00a0985bd305
      Operation: switchover
          State: failed
         Errors: Failed to validate the node and cluster components before the switchover operation.
                 ClusterA::siteA-02 (non-overridable veto): DR partner NVLog mirroring is not online. Make sure that the links between the two sites are healthy and properly configured.
           Node: -
     Start Time: mm/dd/yyyy hh:mm:ss
       End Time: mm/dd/yyyy hh:mm:ss
         Job ID: 19643
 Operation UUID: d719de7e-5a23-11ea-93d9-00a0985bd305
   Command Line: metrocluster switchover
Additional Info: -

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.