Answer

NetApp AFF and FAS controllers can be directly connected to the Cisco UCS fabric interconnects without any upstream SAN switch.

Only four Cisco UCS port types can be used to directly connect to NetApp storage:

  • Storage FC port: Directly connect this port to an FC port on NetApp storage.

  • Storage FCoE port: Directly connect this port to an FCoE port on NetApp storage.

  • Appliance port: Directly connect this port to a 10GbE port on NetApp storage.

  • Unified storage port: Directly connect this port to a NetApp UTA.

 

The licensing and hardware requirements are as follows:

  • A protocol license on the NetApp storage controller is required.

  • A Cisco UCS adapter (initiator) is required on the server. For a list of supported Cisco UCS adapters, see the NetApp IMT.

  • A target adapter on the NetApp storage controller is required.

Additional Information

additionalInformation_text
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.