CONTAP-366417: ONTAP upgrade pauses after five hours
Issue
- ONTAP automated nondisruptive upgrade (ANDU) encounters a pause five hours after initiation:
upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Error: Update timeout occured in State[Giveback]-- Tasks Pending in nodes <> Task Name: do-giveback-job, Action: Ensure that nodes are healthy and try resuming the update operation after some time- Checking the status of the upgrade reveals a timeout due to shelf firmware mismatch:
::> cluster image show-update-progressDetails:Node name Status Status Description-------------------- ----------------- --------------------------------------cluster1-01 waitingcluster1-02 failed Error: Task failed due to timeout Action: Ensure that nodes are healthy and try resuming the update operation after some time.cluster1-03 waitingcluster1-04 waiting10 entries were displayed.Status: Paused - An error occurred in "ONTAP updates" phase. The update cannot continue until the error has been resolved (*shelf firmware mismatch error).Resolve all issues, then use the "cluster image resume-update" command to resume the update.