CONTAP-85802: Disks can report incorrect power on hours
Issue
The power on hours may roll over to zero after approximately 6.7 years, resulting in incorrect display of the power on hours. To correct this, update ONTAP to the fix for this defect, and upgrade drive firmware to the most current from:
[https://mysupport.netapp.com/site/do...rive-firmware]
This issue affects drive models that contain the following Model Number strings. The specific model numbers below are only an example. Please see the drive firmware page for all model types:
Model string - Single example model drive:
HAKPE X316_HAKPE06TA07 (If your model contains HAKPE it is an affected model and can benefit from this fix)
HARIH X316_HARIH06TA07 (If your model contains HARIH it is an affected model and can benefit from this fix)
HARHE X318_HARHE08TA07 (If your model contains HARHE it is an affected model and can benefit from this fix)
HLBRE X381_HLBRE10TSDB (If your model contains HLBRE it is an affected model and can benefit from this fix)
HCBFE X426_HCBFE1T8A10 (If your model contains HCBFE it is an affected model and can benefit from this fix)
HCOBE X423_HCOBE900A10 (If your model contains HCOBE it is an affected model and can benefit from this fix)
HCBEP X425_HCBEP1T2A10 (If your model contains HCBEP it is an affected model and can benefit from this fix)