Transient vifmgr.reach.err events observed after ONTAP upgrade
Applies to
ONTAP 9
Issue
- After upgrading from ONTAP 9.15.1 to 9.17.1, multiple nodes may report repeated
vifmgr.reach.errevents on network ports.- EMS log reports:
vifmgr.reach.err: Network port a0a on node Node2 encountered errors while scanning for reachability. Reachability was detected to the following broadcast domains: -. - VIFMGR log reports
exception occurred:0000003e.000ad85c 001e0233 Mon Jul 20 2026 03:13:55 +09:00 [kern_vifmgr:info:8634] [0x80c90ce00] [Net::Reachability::update] exception occurred finding reachability for port e0g: Internal error. Failed to determine the link status of port "e0g" on node "NODE2". Wait a few minutes, then try the command again.0000003e.000c45ab 00229234 Mon Jul 20 2026 11:32:16 +09:00 [kern_vifmgr:info:8634] [0x80c90ce00] [Net::Reachability::update] exception occurred finding reachability for port a0a-503: Internal error. Failed to determine if port "a0a-503" is registered on node "NODE2". Wait a few minutes, then try the command again.0000003e.000c936b 00237430 Mon Jul 20 2026 13:08:39 +09:00 [kern_vifmgr:info:8634] [0x80c90ce00] [Net::Reachability::update] exception occurred finding reachability for port a0a-483: Internal error. Failed to apply changes to port "NODE2:a0a-483": Error reading reachable MAC addresses from cfmd for port "a0a-483" on node "".0000003e.000e71f8 00298dd9 Tue Jul 21 2026 00:14:59 +09:00 [kern_vifmgr:info:8634] [0x80c90ce00] [Net::Reachability::update] exception occurred finding reachability for port a0a-853: Error reading reachable MAC addresses from cfmd for port "a0a-853" on node
- EMS log reports:
- No reported data access or LIF failover issues.
network port reachability showreports all ports healthy.- Errors occur intermittently after upgrade completion.