EMS "csm.mismatchRemoteDevice" message in event log as cluster LIF not on home port
Applies to
- ONTAP
- Clustered Data ONTAP
Issue
EMS Identifier
Cluster01::> event log show -node Clsuter01-01 -event csm*
or
Cluster01::> event log show -node * -event csm*
Time Node Severity Event
------------------- ------------ ------------- ---------------------------
1/6/2013 10:27:01 Cluster01-01 WARNING csm.mismatchRemoteDevice: CSM connection between source LIF 1024 and destination address 169.254.237.128 might not be optimal for session 0104d29c2732314c. The source is currently connected to clus_sw_01 remote device and the destination is currently connected to clus_sw_02 remote device.
- In the EMS message, the source and destination devices are mismatched
- Verify cluster LIFs are hosted on their home ports:
Cluster01::> network interface show -is-home false -role cluster
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
Cluster clus2 up/up 10.228.178.98/24 Cluster01-01 e0a false