A disk is lost after the motherboard is replaced
Applies to
ONTAP 9
Issue
- A disk is lost after the motherboard is replaced:
- The disk is missing in the command "
node run -node <node_name> disk show -v
" output. - But it can be found in the command "
node run -node <node_name> disk show -a
" output.
- The disk is missing in the command "
- The disk owner is the same, but the system ID is different.
::> node run -node aff200-dal-1a "disk show -a"
DISK OWNER POOL SERIAL NUMBER HOME DR HOME
------------ ------------- ----- ------------- ------------- -------------
0b.00.5 aff200-dal-1b(537127733) Pool0 S396NX0JC42234 aff200-dal-1b(537127733)
0b.00.5P1 aff200-dal-1b(537127675) Pool0 S396NX0JC42234NP001 aff200-dal-1b(537127675)
0b.00.5P2 aff200-dal-1b(537127733) Pool0 S396NX0JC42234NP002 aff200-dal-1b(537127733)
0b.00.5P3 aff200-dal-1b(537127733) Pool0 S396NX0JC42234NP003 aff200-dal-1b(537127733)