scsi.cmd.checkCondition:error on all disks
Applies to
Issue
- Receiving the following errors in the
EMS log
[Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'SSP_EVENT 0x34 on 0a.00.4, TAG 0x7ba4007e, INIT_TAG 0xcdb8: target reset'}
[Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'ABORT TASK on device 0a.00.4 Tag 0x7ba4007e'}
[Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.00.4: Check Condition: CDB 0x28:551af160:0018: Sense Data SCSI:aborted command - (0xb - 0x4b 0x4 0x0)(27).
[Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0a.00.4: request successful after retry #1/#0: cdb 0x28:551af160:0018 (28).
- Errors seen incrementing on the SAS adapter
Cluster:> node run -node Node-01 -command sasadmin adapter_state 0a
State for adapter channel 0a: UP
Invald Disprt Loss Phy Phy
DWord Error Sync Reset Change
PHY STATE Count Count Count Prob Count
--------------------------------------------------------
0 12.0 Gb/s 0 0 0 0 4
1 12.0 Gb/s 0 0 0 0 4
2 12.0 Gb/s 0 0 0 0 4
3 12.0 Gb/s 41456 40043 0 0 4
- SAS cable connecting shelf to controller has been replaced