dfu.clusterIcError event detected after ONTAP upgrade
Applies to
- ONTAP 9
- AFF and FAS
Issue
dfu.clusterIcErrorerror dected during BDFU post ONTAP upgrade:
[node01: dynamic_dev_qual_admin: dfu.firmwareDownloading:info]: Now downloading firmware file /etc/disk_fw/X4013S17337T6NTE.NA55.LOD on 1 disk(s) of plex [Pool0]...
[node01: dynamic_dev_qual_admin: dfu.clusterIcError:error]: HA interconnect error 1 encountered. Unable to download firmware to disk 0n.22 [NETAPP X4013S17337T6NTE NA55]
[node01: dynamic_dev_qual_admin: dfu.fwDownloadFailedResumeIO:debug]: Resume I/O command failed for disk 0n.22 with SCSI return error 15.
- Following next BDFU retry the disk fw upgrade complete:
[node01: bg_disk_fw_update_admin: bdfu.downloadRetryInterval:debug]: Download of disk firmware for 0n.22 will be retried in 25 minutes.[node01: bg_disk_fw_update_admin: bdfu.selected:info]: Disk 0n.22 [NETAPP X4013S17337T6NTE NA54]selected for background disk firmware update.[node01: dynamic_dev_qual_admin: dfu.fwDownloaded:debug]: Firmware downloaded to disk 0n.22 [NETAPP X4013S17337T6NTE NA55]successfully.[node01: config_thread: raid.rg.optrecons.done:debug]: Disk /cyberagent_ai_02_aggr2/plex0/rg0/0n.22 Shelf 0 Bay 22 [NETAPP X4013S17337T6NTE NA55] UID [36305230:54900288:00253841:00000002:00000000:00000000:00000000:00000000:00000000:00000000]: optimized reconstruction completed for 0n.22 in 0:00:00