Will the FAS8300 be PANIC when both two PSUs fail?

Views:
100
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS8300
  • FAS8700 
  • AFF A400
  • AFF C400 

Answer

No. The FAS8300 is not PANIC when both two PSUs fais per Controller.
 
  •  The FAS8300/AFF A400/AFF C400 and FAS8700 system has 4 x PSUs per system

PSUs are plugged directly into the PCM (2 per canister)

PSUs power the midplane and if a failure occurs, will also power the partner PCM

  •  2+2 configuration

Requires power to at least 2 power supplies at all times for proper system operation

Power loss or removal of up to 2 of 4 power supplies from any location will still result in an operational system

Power from each PSU is delivered throughout the system (midplane, fans, partner PCM, local PCM)

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.