When node trigger "nvmem.battery.fccLowCrit" error
Applies to
- FAS2720
- ONTAP 9.8P3
Answer
Bat_Full_Cap
meet below conditions triggernvmem.battery.fccLowCrit
error.- When
Bat_Full_Cap/Amps * hour
<0.45*(0.9* 2.1), ONTAP triggernvmem.battery.fccLowWarn
error. - When
Bat_Full_Cap/Amps * hour
<0.40 *(0.9* 2.1).ONTAP triggernvmem.battery.fccLow
error and shutdown in 24 hours. - When
Bat_Full_Cap/Amps * hour
<0.38 *(0.9* 2.1).ONTAP triggernvmem.battery.fccLowCrit
error and shutdown in 20 mins. Bat_Full_Cap
can be check withsystem sensors
via BMC CLI.
Example:
BMC > system sensors
Sensor Name | Current | Unit | Status | LCR | LNC | UNC | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
Bat_Full_Cap | 1.280 | Amps * hour | ok | na | na | na | na
Additional Information
additionalInformation_text