Skip to main content
NetApp Knowledge Base

What are the port states in storage show expander output?

Views:
1,301
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
HW
Last Updated:

Applies to

  • DS2246
  • DS4246

Answer

How can the port state output of storage show expander from the Data ONTAP command line be deciphered?

The following port states can be used by Data ONTAP to describe the status of a PHY port:

  • OK - PHY is functioning normally
  • EMPTY - No drive is present in bay or no cable present for host ports
  • DIS/INVWD - PHY disabled due to excessive Dword errors
  • DIS/DISPA -  PHY disabled due to excessive disparity errors
  • DIS/LOSWD - PHY disabled due to loss of DWord synchronization
  • DIS/RESET - PHY disabled due to excessive PHY Reset Problem errors
  • DIS/CRC - PHY disabled due to excessive CRC errors
  • DIS/PHCHG - PHY disabled due to excessive phy change events
  • DIS/MIR - PHY disabled due to cluster Mirror bit being set (check partner)
  • DIS/RESV* - PHY disabled to emulate SCSI RESERVE
  • DIS/MAN - PHY was manually disabled (Mfg. test only)
  • DIS/CLK - PHY was disabled due to expander reference clock error.
  • DIS/UNKWN - PHY awaiting initialization by expander firmware.
  • DIS/UNUSD - PHY disabled and unused (Reserved for future use)
  • ???:0xXX - Unable to decode port state XX.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.