VMs are down after zone changes
Applies to
- HPE SN1100E 16Gb 2P FC HBA (Firmware: 12.6.275.12 and Driver: 11.4.33.25)
- VMware ESXi 6.7.0 Update 3
- ONTAP 9
- FCP
Issue
Zone (even without NetApp targets) changes cause ESXi host to lose paths to the NetApp datastore:
localcli_storage-san-fc-events-get:
2021-04-30 11:06:31.430 [vmhba1] RSCN received for PID 000000
2021-04-30 11:06:31.430 [vmhba4] RSCN received for PID 000000
vmkernel.log
:
vmkernel.1:2021-04-30T11:06:52.473Z cpu144:2098801)WARNING: lpfc: lpfc_cmpl_els_plogi:1950: 2:(0):2753 PLOGI failure DID:1219E2 Status:x3/x103 State: x8 Ref: 25 Flags: x60008
EMS.log
:
Fri Apr 30 13:06:31 +0200 [NETAPP-00: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '1b' by initiator port: '10:00:e0:07:1b:xx:xx:xx' address 0x100d00. The target virtual port is: 'NetApp FC Target Port (LPe32000) NETAPP_SVM_01:NETAPP-01_fc_lif_2'.