The Bat_LRN_Active event is appearing simultaneously on all nodes
Applies to
- AFF-A50
- ONTAP 9.16.1P6
Issue
- The Bat_LRN_Active event persisted for over 12 hours
- The event raised concerns regarding battery status and potential system impact
- No hardware errors or warnings were found in BMC/NVRAM battery logs
- The system remained online and operational
Example:
Cluster_A50::> service-event show -instance(system controller service-event show)
Node: node-01Service Event ID: 1Location: NV Battery on Controller ADescription: Bat_Lrn_ActiveTimestamp: Fri Feb 6 00:05:19 2026
Node: node-02Service Event ID: 1Location: NV Battery on Controller BDescription: Bat_Lrn_ActiveTimestamp: Fri Feb 6 00:05:20 2026
Node: node-03Service Event ID: 1Location: NV Battery on Controller ADescription: Bat_Lrn_ActiveTimestamp: Fri Feb 6 00:05:22 2026
Node: node-04Service Event ID: 1Location: NV Battery on Controller BDescription: Bat_Lrn_ActiveTimestamp: Fri Feb 6 00:05:21 2026
ipmi oem battery show=====================DeviceChemistry : LIONChemistryID : 0x1267DeviceName: bq40z50-R4ID: 27100080Manufacturer : InventusFW_Version: B1Manufacturer-date : 12/26/2024GG_HW_RV : 0x00a3GG_FW_RV : 0x0045 0x0304 0x5100 0x04 0x7504PackVersion : A0CellVendorType: IMUSerialNumber : 0x0963Status: Ready…LrnCyclFailureRunCount: 0LrnCyclTotalRunCount: 2LrnCycleStartDate : 26-02-06-00:05LrnCycleStartFCC : 0x047eLrnCycleEndFCC: 0x0000LrnCycleEndDate :LrnCycleEntry : 0x02LrnCycleAttempts : 0x01LrnCycleResult: 0x00LrnCycleStartVDSG : 0x1ff9LrnCycleEndVDSG : 0x1cc7LrnCycleStartTmp : 0x0bafLrnCycleEndTmp: 0x0000LrnCycleCheckSum : 0xd1ChargeOption : 0xf913ChargeCurrent : 0x0400ChargeVoltage : 0x2010ChargeInCurrent : 0x1000ChargeManufID : 0x0040ChargeDevID : 0x000bfru_list========