Takeover not possible: local node missing partner disks due to miscabling
Applies to
- FAS
- ONTAP 9
- ANDU (Automatic non disruptive upgrade)
Issue
- Error message in
Storage Failover Show
during validation step of ANDU (automatic non disruptive upgrade) :
Takeover is not possible: Local node missing partner disks
EMS-LOG-FILE
:
node1 ALERT cf.disk.invent.mismatchalt: Status of some of the disks has changed or the node (node1) is missing 4 disks (detailed logs have been throttled).
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D0DDEA4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:724C29B8:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node1 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D0F63E8:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node1) is missing the disk.
node2 ERROR cf.disk.inventory.mismatch: Status of the disk ?.? (5000CCA0:1D06B56C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000) has recently changed or the node (node2) is missing the disk.
SYSCONFIG -A
:
System Storage Configuration: Single-Path HA
for both nodes
- ActiveIQ errors:
- [High] HA Configuration: Takeover is not possible
- [Medium] Cabling: Shelves with both connections via the same SAS path detected