Issue

  • Both nodes in the cluster report disk shelf fault in EMS

node 1        ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
node 2        ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.

  • Shelf 0 enclosure status is reported as fail and IOM A has VPD fault:

        Enclosure Status: non-critical
        Channel: 0a
        Shelf: 0
        Shelf Type: DS224-12
        Product Serial Number: SHFFXXXX76
        Module Type: IOM12E

        Enclosure:
        Element Status         Status Bytes  Status Descriptions
          1: NONCRITICAL       03,00,02,00   FAIL

        Vendor Unique Element 83-IOM12E: (SAS)
        Element Status         Status Bytes  Status Descriptions
          1 [IOM12E A]    : NONCRITICAL       03,0C,00,20   BACKPLANE VPD FAULT, MASTER, RESERVED
          2 [IOM12E B]    : OK                01,00,00,20   RESERVED     

  • This points to an issue with node node 2, as controller A is configured as this node.

        NetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
         System ID: 0XXX16 (node 2); partner ID: 0XXX16 (node 1)
         System Serial Number: 9XXXXX40 (node 2)

          Controller:         A

        NetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
         System ID: 0XXX16 (node 1); partner ID: 0XXX16 (node 2)
         System Serial Number: 9XXXXX41 (node 1)

         Controller:         B

  • The SP-LATEST-IPMI logs indicate that the chassis LED is turned ON by SAS expander (Shelf):

        tag  origin  fld                                     fault reason                                    count  time
        ---- ------- ----                                    -------------                                   ------ -----
        1    bmc     /chassis-1                              SAS Expander has set the Chassis LED ON         1      Wed Oct  1 23:39:04 2025

        Fault Lights On:
                     /chassis-1  

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.