System show a disk shelf fault
Applies to
- ONTAP 9
 - FAS/AFF
 
Issue
- Both nodes in the cluster report disk shelf fault in EMS
 
node 1        ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
node 2        ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
- 
    
Shelf 0 enclosure status is reported as fail and IOM A has VPD fault:
Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFFXXXX76
Module Type: IOM12EEnclosure:
Element Status Status Bytes Status Descriptions
1: NONCRITICAL 03,00,02,00 FAILVendor Unique Element 83-IOM12E: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12E A] : NONCRITICAL 03,0C,00,20 BACKPLANE VPD FAULT, MASTER, RESERVED
2 [IOM12E B] : OK 01,00,00,20 RESERVED - 
    
This points to an issue with node node 2, as controller A is configured as this node.
NetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
System ID: 0XXX16 (node 2); partner ID: 0XXX16 (node 1)
System Serial Number: 9XXXXX40 (node 2)Controller: ANetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
System ID: 0XXX16 (node 1); partner ID: 0XXX16 (node 2)
System Serial Number: 9XXXXX41 (node 1)Controller: B - 
    
The SP-LATEST-IPMI logs indicate that the chassis LED is turned ON by SAS expander (Shelf):
tag origin fld fault reason count time
---- ------- ---- ------------- ------ -----
1 bmc /chassis-1 SAS Expander has set the Chassis LED ON 1 Wed Oct 1 23:39:04 2025Fault Lights On:
/chassis-1 