System is in mixed path due to drawer issue
Applies to
- ONTAP 9
- FAS/AFF systems
- DS460C
Issue
- After disk replacement, the new drive shows in bypassed state:
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SHJHU1948000XXX
Module Type: IOM12
Disk Elements:
Element Status Status Bytes Status Descriptions
34 [Bay 10]: OK 01,0A,00,00
35 [Bay 11]: CRITICAL 02,0B,00,24 BYPASSED B, FAULT REQSTD
36 [Bay 0]: OK 01,00,00,00
- The nodes are in mixed path configuration:
::> system node run -node <node> -command sysconfig -a
NetApp Release 9.6P3
System ID: 053813XXX (CLUSTER-01); partner ID: 053813XXX (CLUSTER-02)
System Serial Number: 651949000XXX (CLUSTER-01)
System Rev: E3
System Storage Configuration: Mixed-Path
- Replacing the IOM does not resolve the issue.
- After replacing the disk with a spare, the issue remains with the slot.