System fault LED light on and "Overcurrent Protection Fault"
- Views:
- 1,067
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems
- Specialty:
- hw
- Last Updated:
- 2/26/2025, 4:04:37 PM
Applies to
- AFF A220
- AFF A150, ASA A150
- AFF C190
- FAS2720, FAS2750
Issue
- Storage fault LED is on.
- Overcurrent Protection Fault error event can be found in the following command output.
Example:
::> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
Clusternode-01
1 10G Port 1 in Controller A Overcurrent Protection Fault
- SP SHELF FAULT RQSTD error event can be found in the following command output.
Example:
::> system node run -node * storage show fault -v
Enclosure Status: normal
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: xxxxxxxxxxxxxxx
Module Type: IOM12E
Vendor Unique Element 88-IOM12E: (PCM)
Element Status Status Bytes Status Descriptions
1: OK 01,01,80,00 SP SHELF FAULT RQSTD
2: OK 01,01,00,00