Applies to

  • FAS9000
  • ONTAP 9.12.1P4
  • MCCIP

Issue

  • Sysconfig -r  reports multiple disk failed
RAID group /aggrname/plex0/rg2 (partial, block checksums)
 
      RAID Disk Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------        ------------- ---- ---- ---- ----- --------------    --------------
      tparity  2c.33.17      2c    33  17  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      dparity FAILED         N/A                        9324290/ -
      parity   10d.31.17     10d   31  17  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.18      2c    33  18  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data FAILED         N/A                        9324290/ -
      data     10d.31.18     10d   31  18  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.19      2c    33  19  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data FAILED         N/A                        9324290/ -
      data     10d.31.19     10d   31  19  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.20      2c    33  20  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data FAILED         N/A                        9324290/ -
      data     10d.31.20     10d   31  20  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.21      2c    33  21  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data FAILED         N/A                        9324290/ -
      data     10d.31.21     10d   31  21  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.22      2c    33  22  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data FAILED         N/A                        9324290/ -
      data     10d.31.22     10d   31  22  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.23      2c    33  23  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     10b.13.24     10b   13  24  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     10d.31.23     10d   31  23  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.24      2c    33  24  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     10b.13.25     10b   13  25  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     10d.31.24     10d   31  24  SA:B   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     2c.33.25      2c    33  25  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      data     10b.13.26     10b   13  26  SA:A   0  FSAS  7200 9324290/19096145920 9342976/19134414848 (fast zeroed)
      Raid group is missing 6 disks.
  • Sysconfig -a reports old IOM version

                        Shelf 1: DS224-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 2: DS224-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 3: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 4: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 21: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 22: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 23: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120
               Shelf 24: DS460-12  Firmware rev. IOM12B A: 0120  IOM12B B: 0120

  • Ems logs reports
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0v.i2.2L146 Shelf 22 Drawer 2 Slot 9 Bay 21 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1A7D33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0v.i1.0L170 Shelf 22 Drawer 2 Slot 8 Bay 20 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B9AD3:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0v.i1.0L16769 Shelf 24 Drawer 4 Slot 3 Bay 39 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1ADE9F:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.0L157 Shelf 22 Drawer 2 Slot 5 Bay 17 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B13D3:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.0L156 Shelf 22 Drawer 2 Slot 4 Bay 16 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1A9BFB:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.0L16700 Shelf 4 Drawer 2 Slot 6 Bay 18 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B90F7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i2.3L254 Shelf 4 Drawer 2 Slot 0 Bay 12 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B444B:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.1L206 Shelf 4 Drawer 2 Slot 4 Bay 16 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B444F:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.1L247 Shelf 4 Drawer 2 Slot 1 Bay 13 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1B0FD3:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_name/plex1/rg2/0m.i1.0L16708 Shelf 4 Drawer 2 Slot 7 Bay 19 [NETAPP   X377_SEVNE10TA07 NA02] S/N [XXXXXXX] UID [5000C500:DA1ADEA3:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
 
  • Raidgroup come back online after few moments and disk were rediscovered again

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.