Node reports StorageSwitchIfIslConfig_Alert for storage switches with Cluster-HA-Storage RCF
Applies to
- ONTAP 9
- Cisco Nexus C9336C-FX2 switches used for storage connections
- AFF systems with 2 HA pairs connected to the same storage switches
- NS224 disk shelves
Issue
- Cluster-HA-Storage RCF is installed on Cisco Nexus C9336C-FX2 storage switches.
- The
StorageSwitchIfIslConfig_Alert
is reported in the event logs:
[Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: StorageSwitchIfIslConfig_Alert[sw003(FLMXXXXXXXC)/Ethernet1/35].
- The system health alert reports the following details:
::> system health alert show
Node: Node-02
Resource: Ethernet1/35
Severity: Major
Indication Time: Thu Dec 08 14:56:35 2022
Suppress: false
Acknowledge: false
Probable Cause: An ISL link has been detected between storaqe
switch:port sw003(FLMXXXXXXXC):Ethernet1/35 and
switch:port sw004:Ethernet1/35"
Possible Effect: Poor storage performance could result.
Corrective Actions: Disconnect the ISL cable connections between the two switches.