"SinglePathToDiskShelf_Alert" occurs when IOM information cannot be read correctly
Applies to
- DS212C
- DS224C
Issue
- The health alert is received:
Health Monitor process nchm: SinglePathToDiskShelf_Alert
sysconfig -adoes not show IOM B information:
Shelf 0:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 1:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 2:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 3:DS224-12 Firmware rev. IOM12B A: 0120 B: ----
Shelf 4:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
STORAGE-SHELF-PORT.XMLshows IOM status “false disconnected”
1.3 4 Bfalse false disconnected 1
1.3 5 Bfalse false disconnected 2
1.3 6 Bfalse false disconnected 3
1.3 7 Bfalse false disconnected 4
- STORAGE-SHELF.XML reports critical error for IOM:
Shelf Name:2.27Error Identifier:11Error Text:Critical error detected in module "2".Corrective Action:Verify that the shelf module is fully seated and secure. If the problem persists, replace the disk shelf module.