"SinglePathToDiskShelf_Alert" occurs when IOM information cannot be read correctly
Applies to
- DS212C
- DS224C
Issue
- The health alert is received:
Health Monitor process nchm: SinglePathToDiskShelf_Alert
sysconfig -a
does not show IOM B information:
Shelf 0:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 1:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 2:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
Shelf 3:DS224-12 Firmware rev. IOM12B A: 0120 B: ----
Shelf 4:DS224-12 Firmware rev. IOM12B A: 0120 IOM12B B: 0120
STORAGE-SHELF-PORT.XML
shows IOM status “false disconnected
”
1.3 4 Bfalse false disconnected 1
1.3 5 Bfalse false disconnected 2
1.3 6 Bfalse false disconnected 3
1.3 7 Bfalse false disconnected 4