"SinglePathToDiskShelf_Alert "and "DISK REDUNDANCY FAILED" Autosupports are triggered
Applies to
- ONTAP 9
- SAS HBA
- Multi-Path
Issue
- EMS reports "DISK REDUNDANCY FAILED"
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
- EMS reports "SinglePathToDiskShelf_Alert"
Tue Oct 11 23:31:23 +0800 [Nodename: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: SinglePathToDiskShelf_Alert[159491309057xxxxxxxx].
- SYSTEM-HEALTH-ALERT.XML reports the following alert:
Controller Nodename has only a single-path configuration to disk shelf 18.10. This might occur when the controller does not have dual-path configuration to stack 18, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.
- system health subsystem showmay report degraded status:
 - ::> system health subsystem show
 Subsystem Health
 ----------------- ------------------
 SAS-connect degraded
 Environment ok
 Memory ok