Shelf IOM reporting critical status
Applies to
- FAS8300
 - DS224
 
Issue
- Shelf IOM reporting critical status
 STORAGE-FAULT
Enclosure Status: critical
Channel: 0b
Shelf: 21
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXX
Module Type: IOM12B
Element Status         Status Bytes  Status Descriptions
  1 [IOM12B A]    : CRITICAL          02,80,00,E4   ADDITIONAL STATUS AVAILABLE, RESERVED, RESERVED, EXCEPTION DATA VALID, RESERVED
  2 [IOM12B B]    : OK                01,08,00,20   MASTER, RESERVED
- Even post replacing the IOM, , multiple other components like power supplies, fans, temperature sensors etc of the shelf reports NOT INSTALLED and IOM reports critical state:
 STORAGE-FAULT
Power Supplies:
Element Status         Status Bytes  Status Descriptions
  1: NOT INSTALLED     05,00,00,20
  2: NOT INSTALLED     05,00,00,20
Fans:
Element Status         Status Bytes  Status Descriptions
  1: NOT INSTALLED     05,00,00,20
  2: NOT INSTALLED     05,00,00,20
  3: NOT INSTALLED     05,00,00,20
  4: NOT INSTALLED     05,00,00,20
- Issue persists post swapping IOM with a working IOM in the faulty IOM slot(Downtime Needed)
 