Sensor warning : ses.status.currentWarning
Applies to
Issue
- System reports
Severity: ERROR
Message: ses.status.currentWarning: DS212-12 (S/N XXXXXXXXXXXX) shelf 0 on channel 0b current warning for Current sensor 3: internal communication error. This module is on the rear of the shelf on the lower right power supply.
Description: This message occurs when a warning condition is detected in the indicated disk shelf current sensor. The disk shelf might be able to continue operation.
Corrective Action: Verify that the PSU and the AC line are supplying power. Monitor the power grid for abnormalities. If all seems to be normal, replace the PSU. If the problem persists, contact NetApp technical support.
storage fault -v
reports
Cluster::> system node run -node * -c storage show fault -v
2 entries were acted on.
Node: Node1
Enclosure Status: unrecoverable
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: XXXXXXXXX
Module Type: IOM12E
Current Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,01,05
2: OK 01,00,03,D0
3: UNRECOVERABLE 04,00,00,00
4: OK 01,00,03,F3
- Shelf Firmware is not up to date
Shelf 0: DS212-12 Firmware rev. IOM12E A: 0210 IOM12E B: 0210
Shelf 10: DS212-12 Firmware rev. IOM12 A: 0260 IOM12 B: 0260
Shelf 11: DS212-12 Firmware rev. IOM12 A: 0260 IOM12 B: 0260