Skip to main content
NetApp Knowledge Base

Sensor warning : ses.status.currentWarning

Views:
90
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:
4/15/2024, 2:20:32 PM

Applies to

DS212C

Issue

  • System reports 

Severity: ERROR

Message: ses.status.currentWarning: DS212-12 (S/N XXXXXXXXXXXX) shelf 0 on channel 0b current warning for Current sensor 3: internal communication error. This module is on the rear of the shelf on the lower right power supply.

Description: This message occurs when a warning condition is detected in the indicated disk shelf current sensor. The disk shelf might be able to continue operation.

Corrective Action: Verify that the PSU and the AC line are supplying power. Monitor the power grid for abnormalities. If all seems to be normal, replace the PSU. If the problem persists, contact NetApp technical support.

  • storage fault -v reports 

Cluster::> system node run -node * -c storage show fault -v
2 entries were acted on.

Node: Node1

Enclosure Status: unrecoverable
Channel: 0a
Shelf: 0
Shelf Type: DS212-12
Product Serial Number: XXXXXXXXX
Module Type: IOM12E


Current Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,01,05
  2: OK                01,00,03,D0
  3: UNRECOVERABLE     04,00,00,00
  4: OK                01,00,03,F3

  • Shelf Firmware is not up to date 

 Shelf 0: DS212-12  Firmware rev. IOM12E A: 0210  IOM12E B: 0210
Shelf 10: DS212-12  Firmware rev. IOM12 A: 0260  IOM12 B:  0260
Shelf 11: DS212-12  Firmware rev. IOM12 A: 0260  IOM12 B:  0260 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.