SPAutoUpgradeFailedMajorAlert is displayed and SP automatic update is stuck at 5 percent
Applies to
Service Processor (SP)
Issue
- The following alert message appears in EMS after upgrading ONTAP.
[?] Sat Jan 14 11:04:15 JST [node 2: nphmd: hm.alert.raised:alert]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade raised by monitor controller
- SP firmware on
node2
is failing.
::> system service-processor image show
Is
Node Type Image Status Current Version
---------------- ----- ------- ----------- ------- --------
node1
SP
primary installed true 5.8
backup installed false 5.1
node2
SP
primary installed true 5.1
backup installed false 5.1
- From the output of the system service-processor show,
node 2
updates are stuck at 5%.
::> system service-processor show
(system service-processor image update-progress show)
In Percent
Node Progress Start Time Done End Time
---------------- -------- ------------------- ------- -------------------
node1 no 1/14/2023 10:49:43 100 1/14/2023 10:54:03
node2 no 1/14/2023 11:55:42 5 1/14/2023 11:57:21
- Attempted SP manual update but no response.
::> system service-processor image update -node node2 -update-type serial-full
- Accessing the SP via SSH does not respond, so updating SP firmware via BMC is not possible.